STORMFLASH 60 – TECHNICAL FEATURES
Early Streamer Emission (ESE) Air Terminal
NF C 17-102 (edition 2011) and UNE 21186: 2011 sta n dards
ΔT = 60 μSec (Triggering Time Advance T)
70 kA (8/20 µSec) Impulse Current
No need of battery or external power source
304L (Inox) Stainless Steel design – suitable for any environmental conditions
Suitable for use with a variety of down conductors – tape/strip, round conductor, isolated/insulated cables/HVSC Cable etc
20 years warranty
PROTECTION RADIUS AS PER NF C 17-102 (2011)
| Mast Height h (m) | Level I (Very High) | Level II (High) | Level III (Medium) | Level IV (Standard) |
|---|---|---|---|---|
| 2 | 31 | 35 | 39 | 43 |
| 3 | 47 | 52 | 58 | 63 |
| 4 | 63 | 69 | 78 | 85 |
| 5 | 79 | 86 | 97 | 107 |
| 6 | 79 | 87 | 97 | 107 |
| 8 | 79 | 88 | 98 | 108 |
| 10 | 79 | 88 | 99 | 109 |
| 15 | 80 | 89 | 101 | 111 |
| 20 | 80 | 89 | 102 | 113 |
| 45 | 80 | 89 | 105 | 119 |
| 50 | 80 | 89 | 105 | 120 |
| 80 | 80 | 89 | 105 | 120 |
| 100 | 80 | 89 | 105 | 120 |
| Mast Height h (m) | Level I (Very High) | Level II (High) | Level III (Medium) | Level IV (Standard) |
|---|---|---|---|---|
| 2 | 31 | 35 | 39 | 43 |
| 3 | 47 | 52 | 58 | 63 |
| 4 | 63 | 69 | 78 | 85 |
| 5 | 79 | 86 | 97 | 107 |
| 6 | 79 | 87 | 97 | 107 |
| 8 | 79 | 88 | 98 | 108 |
| 10 | 79 | 88 | 99 | 109 |
| 15 | 80 | 89 | 101 | 111 |
| 20 | 80 | 89 | 102 | 113 |
| 45 | 80 | 89 | 105 | 119 |
| 50 | 80 | 89 | 105 | 120 |
| 80 | 80 | 89 | 105 | 120 |
| 100 | 80 | 89 | 105 | 120 |