SIRIUS ESE TERMINAL

Home » topbas » SIRIUS ESE TERMINAL

Description

Standard

  • NF C 17-102 (2011) designed & tested.

Design

  • Non-Electronic ESE.
  • No use of battery or external power source.
  • 304L (Inox) Stainless Steel – suitable for any environmental conditions.

Specification

Testing

  • Delta T, ΔT = 60 µSec (Triggering Time Advance).
  • 204 kA (10/350 µSec) Lightning Impulse Current tested.
  • 70 kA (8/20 µSec) Impulse Current – CPRI (Government of India) tested.
  • CE certified.

Usability

  • Suitable for various down conductors Round/Flat (Bare & Insulated), Cables, etc
Protection radius as per NF C 17-102 (2011)
Mast Height
h (m)
Level I
Very High
Level II
High
Level III
Medium
Level IV
Standard
2 31 35 39 43
3 47 52 58 63
4 63 69 78 85
5 79 86 97 107
6 79 87 97 107
8 79 88 98 108
10 79 88 99 109
15 80 89 101 111
100 80 89 105 120